SOD · 011
SOD Terminal OS · Hassan Secondary Distribution
LIVE
TERMINAL
HASSAN · BAYS 7 / 10 · 11,420 kL/d
BAYS ACTIVE
7 / 10
1
THROUGHPUT
11,420
kL/d
2.4
PUMPS ONLINE
7 / 8
SPILL EVENTS · 24H
1
1
RESTRICTED-ZONE BREACH
2
2
SOP COMPLIANCE
91.4
%
0.8
BAY

Bay-wise Loading / Unloading · CCTV Composite

● LIVE · 10 CAMS · STITCHED
ANPR

Tank Truck Register · ANPR + Turn-Around Time

8 TRUCKS · LAST 12H · AVG TAT 42m
Event KA-05-AC-3104
CLIP · BAY-04
08:12:4408:51:09
EVD-2200 · 00:38TAT 38m 25s
INDKA-05-AC-3104
BPCL CarrierHSD
IN 08:12:44OUT 08:51:09
completedBAY BAY-04
Event KA-01-MH-7821
CLIP · BAY-02
08:18:0209:02:51
EVD-2201 · 00:38TAT 44m 49s
INDKA-01-MH-7821
IOCL LogisticsMS
IN 08:18:02OUT 09:02:51
completedBAY BAY-02
Event MH-12-DK-4490
CLIP · BAY-09
08:24:31
EVD-2202 · 00:38TAT 32m 11s
INDMH-12-DK-4490
HPCL TankerATF
IN 08:24:31OUT
loadingBAY BAY-09
Event TN-22-BL-1102
CLIP · BAY-07
08:30:18
EVD-2203 · 00:38TAT 26m 02s
INDTN-22-BL-1102
Reliance BPHSD
IN 08:30:18OUT
loadingBAY BAY-07
Event AP-09-TR-6655
CLIP · BAY-05
07:48:1108:39:44
EVD-2204 · 00:38TAT 51m 33s
INDAP-09-TR-6655
Nayara EnergyMS
IN 07:48:11OUT 08:39:44
completedBAY BAY-05
Event GJ-04-PT-2231
CLIP · BAY-01
07:32:5508:19:08
EVD-2205 · 00:38TAT 46m 13s
INDGJ-04-PT-2231
BPCL CarrierHSD
IN 07:32:55OUT 08:19:08
completedBAY BAY-01
Event RJ-14-CN-9087
CLIP · BAY-03
08:36:40
EVD-2206 · 00:38TAT 19m 48s
INDRJ-14-CN-9087
IOCL LogisticsATF
IN 08:36:40OUT
loadingBAY BAY-03
Event DL-01-LR-5512
CLIP · BAY-06
07:11:2208:24:55
EVD-2207 · 00:38TAT 1h 13m
INDDL-01-LR-5512
HPCL TankerMS
IN 07:11:22OUT 08:24:55
completedBAY BAY-06
ZON

Fire-Zone & Restricted Areas

  • Fire Zone A — Manifold
    OK
    Persons: 0Temp: 33.2°CCams: 3
  • Fire Zone B — Pump House
    WARN
    Persons: 1Temp: 36.8°CCams: 3
  • Fire Zone C — Decanting
    OK
    Persons: 4Temp: 32.1°CCams: 3
  • Restricted — Tankage
    CRIT
    Persons: 1Temp: 30.4°CCams: 3
PMP

Pump House Telemetry

PUMPPRODRPMVIB (mm/s)TEMPSTATUSHEALTH
P-01MS14201.2052.0°COK
P-02HSD14571.5053.4°COK
P-03ATF14941.8054.8°COK
P-04HSD15312.1056.2°CWARN
P-05MS15681.2057.6°COK
P-06HSD16051.5052.0°COK
P-07ATF14221.8053.4°CCRIT
P-08HSD14592.1054.8°COK
FLW

Product Transfer · Flow Rate (L/min)

MS HSD ATF
VLV

Valve Operation Timeline

V-203
transition
08:30:00
scada
V-204
open
08:31:70
operator: R.Iyer
V-205
open
08:32:14
auto-agent
V-206
closed
08:33:21
operator: S.Singh
V-207
open
08:34:28
scada
V-208
transition
08:35:35
operator: R.Iyer
V-209
closed
08:36:42
auto-agent
V-210
open
08:37:49
operator: S.Singh
V-211
open
08:38:56
scada
V-212
closed
08:39:30
operator: R.Iyer
V-213
transition
08:40:10
auto-agent
V-214
open
08:41:17
operator: S.Singh
V-215
closed
08:42:24
scada
V-216
open
08:43:31
operator: R.Iyer
VALVE-WATCH AGENT
V-208 opened out of declared sequence at 08:36:58. SOP step 3 expected before 4. Cross-checked with operator console — no manual override registered. Auto-flagged for SCADA reconciliation.
SAF

Safety & Compliance · Live Feed

  • 08:42:11Decanting
    Spill sensor S-04 triggered · BAY-07
    agent · Spill-Vision
  • 08:41:02Loading
    Helper without goggles · BAY-03
    agent · PPE-Guard
  • 08:40:18Pump House
    Restricted entry — 1 person near pump P-07
    agent · Geo-Fence
  • 08:39:44BAY-04
    Bonding cable not detected · T-3104
    agent · SOP-Sentinel
  • 08:38:55Fire Zone A
    Fire-zone smoke baseline restored
    agent · Vision/Thermal
  • 08:38:11Loading
    Driver mobile phone use · BAY-02
    agent · Driver-AI
  • 08:37:30BAY-09
    Decanting SOP step 4/7 verified · T-3098
    agent · SOP-Sentinel
  • 08:36:58Manifold
    Valve V-208 opened out of sequence
    agent · Valve-Watch
ASK

Ask BLUE · Investigation Panel

SAVED QUERIES
QUERY · 08:42
"Replay decanting SOP for T-3104 with PPE overlay"
BAY07-N02
BAY07-N02
08:40:12
PPE OKNORMAL
BAY07-S01
BAY07-S01
08:41:19
BOND MISSALERT
PUMP-W04
PUMP-W04
08:42:26
HOTSPOTWARN
MNFD-E11
MNFD-E11
08:43:33
SEQ ERRALERT
BLUE · CORRELATION
Driver T-3104 entered decanting envelope at 08:39:44. Bonding cable not detected for 38 seconds. Helper crossed restricted line at 08:40:18. Recommended: hold tanker, issue SOP-3 retraining cue, attach evidence pack EVD-2241 to incident.